Home > Products

Products

Check our Products

RTPFC Panel

Real Time Power Factor Correction Panel (RTPFC) offers a complete solution for Automatic Power Factor Correction employing thyristor based switching of capacitors.

Read More

APFC Panel

Automatic power factor correction Panel has contactor-based switching. It has a microcontroller based programmable controller which switches the capacitor banks of suitable capacity automatically in multiple stages by directly reading the reactive load (KVAR) which works in the principle of VAR sensing tends to maintain the PF to 0.99.

Read More

Active Harmonic Filters

Active harmonic filters are parallel filters (which means the current doesn’t go through the filter) that are used to mitigate harmonics to tolerable levels as defined by IEEE-519. Active filters use a set of transistors and capacitors to filter (or clean) the current wave by injecting inverse currents to cancel out the undesired harmonic components.

Read More

Passive Harmonic Filters

The passive filters are used in order to protect the power system by restricting the harmonic current to enter the power system by providing a low impedance path. Passive filters consisting of tuned series L-C circuits, are the most popular, and may produce unwanted side effects, particularly in the presence capacitor which is used for power factor correction.

Read More

Hybrid Filters

Brawn Energy also offering custom built Hybrid Panels (Reactive Compensations + Harmonic Filtration) that combine the benefits of reactive power compensation and harmonic filtration in a single package. These panels can not only ensure near unity PF but can ensure that the harmonics stay within levels as specified by IEEE 519 or other applicable standards.

Read More

Detuned Filters

Detuned filters are three phase inductor connected in series with capacitor to attenuate the amplification of harmonics in harmonic rich network and protect the different component of the installation. Detuned harmonic filter do not destroy harmonic components in the system.

Read More

Static Var Generator(SVG)

SVG also known as real time power factor compensators or instantaneous stepless reactive power compensators are the ultimate answer to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications. The SVG correct power factor for inductive as well as capacitive loads instantly.

Read More

Thyristor Switching Modules(TSM)

Thyristor Switching Modules are free of mechanical wear and tear, operate without noise and provide practically transient free switching eliminating inrush currents which are associated with Electromechanical Contactor Switching. An unlimited number of switching operations, without applying significant stress to the capacitors.

Read More